As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT THE UPPER CARGO COMPT FS 1500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS AND FILLERS IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 3-12-00.