What was found
DURING A MAINTENANCE VISIT FOUND A 2.5 INCH CRACK TO THE UPPER RIB ON THE NR 2 STUB WING AT STA XFS 250.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-28-0, 57-3-2, 57-3-0 AND 51-1-20D.