What was found
DURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL AND MISSING FASTENERS AT FS 1300 TO 1320 AND L4R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND 51-1-24.