As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PLANK NR 2 STA 233 TO 315, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 5-16-00.