As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE FLOOR PLANK AT STA 1240 TO 1460 ROW 10 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 4-17-00.