What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE KEEL BEAM AT STA 815 - 781 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-4, 51-1-21 AND EO NR 00-047 WITH APPROVED 8110-3 DATED 4-20-00. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).