What was found
DURING A MAINTENANCE VISIT FOUND A SMALL DENT AT FS 850 AND L9R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-20D, 51-1-21 AND EO NR 00-047 WITH APPROVED 8110-3 DATED 4-24-00.