What was found
DURING A MAINTENANCE VISIT FOUND A HOLE IN THE INTERCOSTAL AT FS 560 - 580 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND 51-1-21.