What was found
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 520-XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. WITHIN ALLOWABLE LIMITS IAW DC-8 SRM 53-2-3, FIG 12 AND EO NR 00-047 WITH APPROVED 8110-3 DATED 5-7-00.