What was found
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1260 - 1380 XCW 22 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-3, FIG 12 AND EO NR 00-047 WITH APPROVED 8110-3 DATED 5-7-00.