What was found
DURING A MAINTENANCE VISIT FOUND A MISDRILLED HOLE IN THE FRAME RADIUS AT STA 920 AND L12R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D, 51-1-4 AND EO NR 00-047 WITH APPROVED 8110-3 DATED 3-13-00.