What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON 35L BETWEEN STA 1586 - 1568 LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-21, 51-1-20D AND EO NR 00-047 WITH APPROVED 8110-3 DATED 4-25-00. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).