What was found
DURING A MAINTENANCE VISIT FOUND THE ATTACHMENT LUG BROKEN OFF TOP OF RT MAIN LANDING GEAR DRAG LINK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH APPROVED 8110-3 DATED 6-16-00.