What was found
DURING A MAINTENANCE VISIT, FOUND NLG DRAG BRACE RT UPPER ATTACH LUG BUSHING WAS PITTED. AFTER REMOVAL OF BUSHING, PITTING WAS FOUND ON THE ID OF THE BRACE ATTACH POINT. FINAL ID AFTER CORROSION REMOVAL IS 2.601, MAX. ALLOWABLE IS 2.577. *S/D* FABRICATED AND INSTALLED NEW BUSHING IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-03832 AND DAC ACTION 349656 AND DC-8 OHM 32-2-0 FIGURE 2.