What was found
DURING MAINTENANCE VISIT, FOUND FRAME 1020 WITH MISDRILLED HOLES BETWEEN LONGERONS 7 AND 9 RIGHT. FABRICATED AND INSTALLED REPAIR STRAP IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH E84-R81, AREA TREATED IAW DC-8 SRM 51-1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE VISIT, FOUND FRAME 1020 WITH MISDRILLED HOLES BETWEEN LONGERONS 7 AND 9 RIGHT. FABRICATED AND INSTALLED REPAIR STRAP IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH E84-R81, AREA TREATED IAW DC-8 SRM 51-1-8.