What was found
DURING MAINTENANCE VISIT, FOUND FRAME 1360 WITH MISDRILLED HOLES AT LONGERON 9 RIGHT. REMOVED GUSSET, REMOVED DAMAGED AREA, FABRICATED AND INSTALLED NEW SPLICE, STRAPS AND GUSSET IAW FAA APPROVED ACMI SKETCH SK98390, DC-8 SRM 51-1-21 AND AREA TREATED IAW DC-8 SRM 51-1-8.