What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, LT MLG, RETRACT CYL A-PIN REPAIR PER CUSTOMER REQUEST IAW MA A13210-01:03 S/B 32-102 REF. AD 71-25-09. ACCOMPLISHED INSPECTION FOUND CORROSION IN PIN BOSS.. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED IAW FAA APPROVED TENNESSEE TECH SERVICES DER ENGINEERING SKETCH NR EO- 99-085 WITH APPROVED 8110-3, DATED MAY 21, 1999. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).