What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, RT MLG, RETRACT CYL. A PIN REPAIR PER CUSTOMER REQUEST IAW MA AI 3210-01:03 S/B 32-102, REF AD 71-25-09. ACCOMPLISHED INSPECTION, FOUND CORROSION, IN PIN BOSS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC8 SRM 51-1-8. REPAIRED IAW FAA APPROVED TENNESSEE TECH SERVICES DER ENGINEERING SKETCH NR EO-99-085 WITH APPROVED 8110-3 DATED MAY 21, 1999. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).