What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, LT MLG RETRACT PIN BOSS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REBUSHED LT MLG RETRACT PIN BOSS BORE IAW AAR FAA APPROVED DER ENGINEERING SKETCH NR 99-417 AND EMERY WORLDWIDE MA NR AI-3210-01:03. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).