What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 1385 AND LONGERON 26 LEFT, DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).