Service difficulty report · Sensor · Lear 60LEAR

Difficulty date
July 22, 2019
Submitted
July 25, 2019
Operation
Air carrier
Aircraft
N56
Make and model
Lear 60LEAR
Aircraft serial
033
Aircraft time
11,402 hours, 5,212 cycles
Part
Sensor
Part number
2561
Part serial
9842165
Condition
Failed
Location
Electrical Sys
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PER PIC,EPM SHOWED THE RIGHT GENERATOR AMPS ABOVE 450 AMPS, WITH A MASTER CAUTION. THE LEFT AMPERAGE SHOWED NORMAL AT ABOUT 190 AMPS. THE CAUSE WAS DETERMINED TO BE CURRENT SENSOR FAILURE. SENSOR WAS REPLACED. NO FURTHER ACTION REQUIRED.