SDR SABA980044

Service difficulty report · Bypass Valve · Bag JETSTM3201

Difficulty date
September 9, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N952AE
Make and model
Bag JETSTM3201
Aircraft serial
952
Part
Bypass Valve
Part number
7445B
Condition
Failed
Location
Hydraulic System
Stage of operation
CL
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 5202 - CLT-LYH - AFTER TAKEOFF AND CLIMB-OUT, AIRCREW REPORTED A CONSTANT GEAR WARNING HORN. AIRCRAFT RETURNED TO CLT. NO INFLIGHT EMERGENCY WAS DECLARED. AIRCRAFT LANDED AT CLT WITH NO OTHER PROBLEMS. MAINTENANCE FOUND THE BYPASS PIN POPPED. RESET PIN, PIN POPPED AGAIN. REMOVED AND REPLACED VALVE. BLEED HYD SYSTEM. SYSTEM OPS CHECKED GOOD. (M)