What was found
DURING CLIMBOUT FROM MSP THE NUMBER THREE PNEUMATIC FAIL LIGHT ILLUMINATED. FOUND DUCT AAM7235-501 LEAKING AFT OF AFT WALL NUMBER THREE PACK BAY. PERFORMED REPAIR OF CHAFED DUCT, REPOSITIONED AND LEAK CHECKED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CLIMBOUT FROM MSP THE NUMBER THREE PNEUMATIC FAIL LIGHT ILLUMINATED. FOUND DUCT AAM7235-501 LEAKING AFT OF AFT WALL NUMBER THREE PACK BAY. PERFORMED REPAIR OF CHAFED DUCT, REPOSITIONED AND LEAK CHECKED.