What was found
DURING HEAVY CHECK, LEVEL TWO CORROSION WAS DISCOVERED AT STA 1887 LBL27 TO RBL80 ON CABIN FLOOR SUPPORTS. REMOVED FIVE EACH FLOOR SUPPORTS, FABRICATED FIVE EACH FLOOR SUPPORTS PER SRM 530001 AT STATION 1887 FROM LBL27 TO RBL80. TREATED AND PRIMED PER SRM 512101. INSTALLED PER SRM 533101.