As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON FLOORBOARD SUPPORT INTERCOSTAL STATION 1887 LBL 39 TO 57. MATERIAL ID FOR FLOOR SUPPORT AND FABRICATED FLOOR SUPPORT IAW DC10 SRM 531601 VOL 3. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2. INSTALLED IAW DC10 SRM 513501 VOL 2.