What was found
ABI - THIS LEVEL 2 FINDING WAS FOUND DURING AN MBV INSPECTION REFERENCE CRIC NR 27872 SERVICE DOOR AFT SILL CORRODED. INSTALLED NEW AFT SERVICE DOOR SILL IAW EMB 145 SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - THIS LEVEL 2 FINDING WAS FOUND DURING AN MBV INSPECTION REFERENCE CRIC NR 27872 SERVICE DOOR AFT SILL CORRODED. INSTALLED NEW AFT SERVICE DOOR SILL IAW EMB 145 SRM 51-40-02. (M)