Service difficulty report · Sensor · Emb EMB145LR

Difficulty date
December 9, 2012
Submitted
January 11, 2013
Operation
Air carrier
Aircraft
N902BC
Make and model
Emb EMB145LR
Aircraft serial
14500887
Aircraft time
20,759 hours, 17,312 cycles
Part
Sensor
Condition
Defective
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON FLIGHT 4198 THE CREW REPORTED THEY RECEIVED A BLEED 1 OVERTEMP MESSAGE. THE CREW COMPLIED WITH AOM PROCEDURES AND NOTIFIED SOC, OPS & FLIGHT ATTENDANT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. TROUBLESHOT IAW EMB 145 FIM 36-11-00-810-803A FOUND BAGGAGE COMPARTMENT OUTLET TEMP SENSOR BAD REMOVED AND REPLACED IAW EMB 145 AMM 36-20-01 PERFORMED OPC IAW EMB 145 AMM 36-00-00-700-803-A OPC GOOD NO FURTHER DEFECTS NOTED. THE AIRCRAFT WAS RETURNED TO SERVICE.