Service difficulty report · Wire · Emb EMB135KL

Difficulty date
July 10, 2013
Submitted
July 11, 2013
Operation
Air carrier
Aircraft
N849AE
Make and model
Emb EMB135KL
Aircraft serial
145716
Aircraft time
25,005 hours, 22,465 cycles
Part
Wire
Condition
Broken
Location
Overheat Detect
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW RECEIVED A BLEED LEAK WARNING DURING CRUISE. CREW FOLLOWED PROCEDURES AND COULD NOT CLEAR. DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. FOUND BROKEN DUCT LEAK SENSOR BY JOINT 30. REPAIRED WIRE IAW WM 20-30-00 & 20-21-00. REINSTALED THERMAL SWITCH IAW AMM 36-20-02. ACFT RETURNED TO SERVICE.