What was found
DURING MBV INSPECTION, QA FOUND THE FUSELAGE SKIN GOUGED INSIDE LT PYLON BETWEEN PANELS 414CB & 414DB. ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. PERFORMED PERMANENT REPAIR ON THE FUSELAGE SKIN GOUGE INSIDE LT PYLON BETWEEN PANELS 414CB & 414DB IAW ERS-EM-53MR-926. ACFT WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIR MATERIALS, DOUBLER 2024T3 .063, ANGLE 2024T3 .063, FILLER 2024T3 .063, SHIM 2024T3 .063, BUSHING PN EPNEM53EP1489-01.