What was found
AFTER REMOVAL OF CORROSION FROM THE RT MLG FWD SIDE BRACE FITTING & INSTALLATION OF NEW BEARING, FOUND THE BEARING WAS LOOSE & HAD PLAY INSIDE THE FITTING. THE ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. PERFORMED REPLACEMENT OF RT MLG FWD SIDE BRACE FITTING IAW ERS-EM-57MR-450. REPAIR MATERIALS, 145-67115-606, REPLACEMENT FITTING, SHIM PN 145-67138-005, SIM PN 145-67138-003, SHIM PN 145-138-001.