Service difficulty report · Warning System · Emb ERJ170200LR

Difficulty date
June 2, 2016
Submitted
June 7, 2016
Operation
Air carrier
Aircraft
N222NS
Make and model
Emb ERJ170200LR
Aircraft serial
17000528
Aircraft time
1,006 hours, 822 cycles
Part
Warning System
Condition
False Activation
Location
Anti-Ice Sys
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ANTI-ICE WING LEAK 2, MSG CAME ON WITH NO INDICATION OF ICE CONDITION, BUT IN CLOUDS CLIMBING THROUGH 240FL AT 290 KIAS AT 4 C SAT. PERFORMED NON-NORMAL CHECKLIST & MSG CLEARED, THEN REAPPEARED REPEATEDLY DESPITE COMPLETING ALL ABNORMAL CHECKLIST. HAD EICAS MSG ANTI-ICE WING 2 LEAK PRESENTED AT FL310 & IN ICING CONDITIONS. DID ABNORMAL PROCEDURE & MSG CLEARED, THEN PRESENTED ITSELF DURING DESCENT TO CLEAR ACFT OF ICING CONDITIONS. SEVERAL TIMES CLEARING, THEN RE-PRESENTING THE SAME ANTI-ICING WING 2 LEAK MSG. R & R CERAMIC INSERT IAW AMM 36-20-01, R & R AMS CONTROLLER 2 IAW AMM 21-00-01 & RESET NVM IAW 45-45-00. PERFORMED MULTIPLE WING ANTI-ICE TEST IAW AMM 30-11-00. OPERATIONS CHECKED GOOD AT THIS TIME.