What was found
ELECTRICAL BURNING ODOR ENROUTE, DESCENT & LANDING, ODOR IN COCKPIT AND NEAR F/A JUMPSEAT. INSPECTED AND FOUND THE CAPTAIN'S FLOODLIGHT RHEOSTAT TO BE AT FAULT. REMOVED AND REPLACED THE INSTRUMENT AND CONTROL PANEL LIGHT PANEL ASSEMBLY IAW AMM 20-13-10 AND OPS CHECKED GOOD IAW 33-12-00, RAN BOTH BLEEDS, PACKS, WINDSHIELD HEAT, ALL COCKPIT LIGHTS & SYSTEMS, NO SMOKE OR BURNING ELECTRICAL ODOR NOTED.