What was found
FWD SIDE OF FLOORBEAM FS280.00 HAS A I INCH CRACK AT LBL9.00-C/A-REPAIRED FS280.00 ON THE LH SIDE IAW SRM 53-11-41. REFERENCE E678820 FOR EWIS CLEANING OF THE AREA. REFERENCE E678821 FOR APPLICATION OF PROTECTIVE COATING OF THE AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD SIDE OF FLOORBEAM FS280.00 HAS A I INCH CRACK AT LBL9.00-C/A-REPAIRED FS280.00 ON THE LH SIDE IAW SRM 53-11-41. REFERENCE E678820 FOR EWIS CLEANING OF THE AREA. REFERENCE E678821 FOR APPLICATION OF PROTECTIVE COATING OF THE AREA.