- Difficulty date
- January 5, 2019
- Submitted
- January 7, 2019
- Operation
- Air carrier
- Make and model
- Emb EMB145LR
- Aircraft serial
- 145740
- Aircraft time
- 37,521 hours, 33,095 cycles
- Part
- Controller
- Condition
- Malfunctioned
- Location
- Window Heat
- Stage of operation
- CL
- How discovered
- O
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
W/S 1 HEAT FAIL ON CLIMBOUT. HEARD CLICKING NOISE. C/A-DEFERRED W/S HEAT AS PER MEL 30-24 AUTH 010172DM-C M-PROCEDURES COMPLIED WITH. REMOVED AND REPLACED LT WINDSHIELD TEMP CONTROLLER IAW AMM 30-42-01. PERFORMED OPERATIONAL TEST OF WINDSHIELD HEATING SYSTEM IAW AMM 30-42-00. OPS TEST GOOD. MEL ITEM RESTORED.