What was found
SHEAR CLIP LOCATED AT FR 88 JUST OTBD OF STR 28R HAS CORROSION ON INBD SIDE (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED SHEAR CLIP AT FR 88 JUST OUTBOARD OF STRG 28R IAW EMB 175 SRM 51-40-08. SEE WIPS AND TASKS FOR DETAILS
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR CLIP LOCATED AT FR 88 JUST OTBD OF STR 28R HAS CORROSION ON INBD SIDE (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED SHEAR CLIP AT FR 88 JUST OUTBOARD OF STRG 28R IAW EMB 175 SRM 51-40-08. SEE WIPS AND TASKS FOR DETAILS