What was found
EMERGENCY DECLARED BLEED 1 FAIL RAN QRH. MESSAGE CLEARED BLEED FAIL AGAIN RAN QRH. MESSAGE CLEARED BLEED 1 FAIL AGAIN DIVERTED MIA (TRANSFERRED TO NRWC #760-MIA-00785)-C/A-FOLLOWING FIM TASK# 36-11-00-810-815, REMOVED AND REPLACED LH BLEED TEMPERATURE SENSOR IAW AMM# 36-14-03, PERFORMED #1 ENGINE PNEUMATIC BLEED SYSTEM OPS CHECK AND FOUND SYSTEM OK IAW AMM# 36-11-00. SEE NWRC #760-MIA-00785 FOR WORK PERFORMED.