Service difficulty report · Sensor · Emb ERJ170100STD

Difficulty date
January 11, 2024
Submitted
January 14, 2024
Operation
Air carrier
Aircraft
N760MQ
Make and model
Emb ERJ170100STD
Aircraft serial
17000294
Aircraft time
24,003 hours, 21,106 cycles
Part
Sensor
Part number
6007300
Condition
Failed
Location
Break Temp
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB AT AROUND 400 FT BRK OVERHEAT AND LG TEMP EXCEEDANCE EICAS MESSAGES. RIGHT OB TEMP FLUCTUATING MAJORLY. ON CLIMB. STABILIZED IN FLIGHT AND BRK OVERHEAT EICAS MESSAGE WENT AWAY. BRK OVERHEAT EICAS MESSAGE CAME BACK ON DURING TAXI IN. SAME RIGHT OB BRAKE TEMP FLUCTUATING RAPIDLY.-C/A-REMOVED AND REPLACED #4 BRAKE TEMP SENSOR IAW EMB 170 AMM 32-47-01 OPS TEST GOOD MEL ITEM RESTORED MEL CLEARED