What was found
FWD CARGO DOOR CUTOUT LWR SILL UPPER SECTION HAS CORROSION BELOW FIRST AND SECOND LOWER FRAME FITTINGS. (MAJOR REPAIR) (LEVEL 2 CORROSION). RAR FWD CARGO DOOR CUTOUT LWR SILL IAW EMB 175 SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO DOOR CUTOUT LWR SILL UPPER SECTION HAS CORROSION BELOW FIRST AND SECOND LOWER FRAME FITTINGS. (MAJOR REPAIR) (LEVEL 2 CORROSION). RAR FWD CARGO DOOR CUTOUT LWR SILL IAW EMB 175 SRM 51-40-08