What was found
AFT GALLEY FLOOR STRUCTURE, THE RH SHEAR PANEL HAS CORROSION AT MULTIPLE LOCATIONS. FR 87-88. SSI 53-23-005.(LEVEL 2 CORROSION). RAR THE AFT GALLEY FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR 87-88 IAW ERJ 175 SRM 51- 40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT GALLEY FLOOR STRUCTURE, THE RH SHEAR PANEL HAS CORROSION AT MULTIPLE LOCATIONS. FR 87-88. SSI 53-23-005.(LEVEL 2 CORROSION). RAR THE AFT GALLEY FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR 87-88 IAW ERJ 175 SRM 51- 40-08