As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SSI 53-10-027 RH CENTER FLOOR BEAM HAS MULTIPLE AREAS OF CORROSION FROM FR 13-17. (MAJOR REPAIR) (LEVEL 2 CORROSION). BLENDED TO REMOVE CORROSION IN MULTIPLE AREAS ON RH CENTER FLOOR BEAM FROM FR 13- TO THE MIDDLE OF FR16 IAW ERJ 175 SRM 51-10-03. MULTIPLE AREAS ON RH CENTER FLOOR BEAM FROM FR 13- TO THE MIDDLE OF FR16 WAS FOUND TO BE WITHIN ALLOWABLE LIMITS IAW ERJ 175 SRM 53-10-10/AD01 AND PERFORMED A PERMANENT REPAIR ON RH CENTER BEAM AT FR17. IAW ERJ 175 SRM 53-10-10RE 01P FIGURE 202.