Service difficulty report · Warning Message · Emb ERJ170100SU

Difficulty date
July 4, 2026
Submitted
July 6, 2026
Operation
Air carrier
Aircraft
N780AH
Make and model
Emb ERJ170100SU
Aircraft serial
17000131
Aircraft time
40,258 hours, 30,713 cycles
Part
Warning Message
Condition
False Activation
Location
Hyd Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HYD 2 HI TEMP, FOLLOWED BY HYD 2 OVERHEAT. QRH PROCEDURES WERE COMPLIED WITH. HYD 2 OVERHEAT REMAINED FOR REST OF FLIGHT. DECIDED TO DIVERT. EMERGENCY DECLARED PERFORMED HYD SYS 2 EXTERNAL LEAK CHECK AND CHECKED DIFFERENTIAL PRESSURE INDICATORS OF HYD 2 FILTER MANIFOLD AND CASE DRAIN PER AMM 29-10-00-790-801-A, 29-11-05-200-801-A AND 29-11-07-200-801-A. NO LEAKS NOTED, NO DPS POPPED. OPENED UP ENG 2 COWLINGS PER AMM 78-30-01-910-801-A/-802-A AND CHECKED FOR LEAKS OR DAMAGE AROUND HYD 2 EDP, NO LEAKS OR DISCREPANCIES NOTED. PERFORMED ENG RUNS WITH FLT CREW FOR 30 MIN IN ATTEMPT TO REPLICATE HI TEMP ISSUE, HYD SYS 2 TEMPERATURE CONSISTENLY APPROX 58 C, NO DISCREPANCIES NOTED. SEE EAML 116802074 FOR FURTHER DETAILS AND CORRECTIVE ACTION