What was found
CORROSION ON LH TRACK IN MULTIPLE LOCATIONS BETWEEN FRS 18-20, Y=-10". (MAJOR REPAIR) (LEVEL 2 CORROSION) BLENDED ON FWD LH SEAT TRACK PER EMB 175 SRM 51-10-03. BLENDED 3EA AREAS. BLEND 1 MEASURES L=2.0" W=.8" D=.042", BLEND 2 MEASURES L=2.1" W=.9" D=.040", BLEND 3 MEASURES L=1.8" W=.9" D=.025" AREAS ARE FOUND TO BE OUT OF LIMITS PER EMB 175 SRM 53-10-10/AD01. LOCATED AND DRILLED NEW FWD LH SEAT TRACK (PN: 170-03264-001) PER EMB 175 SRM 51-40-02. RESTORED FINISH TO LH FWD SEAT TRACK PER EMB-175 SRM 51-23-06, ETN-EJ-51- 015. APPLIED PER EMB-175 CPM 51-25-00. INSTALLED STAINLESS STEEL STRIPS TO LH FWD SEAT TRACK PER EMB-175 AMM 53- 01-39-400-804-A. REMOVED AND REPLACED LH FWD SEAT TRACK FR12-FR20 Y=-10 PER EMB 175 SRM 51-40-08.