BLEED 2 OVERPRESSURE AT 2,000 FT. RAN QRH, MESSAGE EXTINGUISHED YET LOOKING ON ECS PAGE BLEED, 2 VALVES SHOWED FAILED CLOSED ALONG WITH HIGH PRESSURE STILL PRESENT. DECIDED TO PUSH OUT BLEED 2 AND KEEP OFF REMAINDER OF FLIGHT. BLEED VALUE EVENTUALLY RETURNED TO A NORMAL VALUE AFTER RESELECTING THE BLEED 2 OFF. R & R RT OVERPRESSURE SWITCH, IAW AMM 36-14-01. OPC GOOD IAW AMM 36-11-00. REF NRWC 036-DFW-05938 AND TURNOVER FOR TECH SUPPORT WORK SCOPE FOR WORK PERFORMED REF AML PG 115003048 ITEM 1.