What was found
DURNG BRIDGE INSPECTION, MAINTENANCE FOUND THE NR 2 ENGINE CONDITION LEVER CABLE MISROUTED AND CHAFING INTO A SUPPORT BRACKET AT 90VU, BETWEEN FRAME 12 AND 13. SUPPORT BRACKET WAS REPAIRED BY INSTALLING A PIECE OF .071 ALUMINUM OVER DAMAGE IAW SRM 53-00-00. CABLE WAS REMOVED, INSPECTED, AND PROPERLY ROUTED. TENSION WAS ADJUSTED IAW JIC 61-21-21. ACFT WAS RETURNED TO SERVICE. (W)