What was found
DFW - DURIGN COMPLIANCE OF EO E9-2700-001 (AD 93-22-10) REPETITIVE INSPECTION OF AILERON CONTROL SYSTEM. THE FLAP INTERCONNECT ROD APPEARED TO HAVE SEVERAL CRACKS JUST INBOARD OF BEARING SLEEVES. THE INTERCONNECT ROD WAS REPLACED AS A PRECAUTIONARY STEP. FURTHER INSPECTION AND EVALUATION OF THE ROD WILL CONTINUE BY SIMMONS AND ATR. OPS CHECK SATISFACTORY AS PER GPM. AIRCRAFT WAS RETURNED TO SERVICE. (M)