DURING D CHECK INSPECTION STA 651 FLOORBEAM, BL O REPAIR ANGLE HAS A FASTNER GIVING SHORTED ON P/N 65C34537-11 ANGLE. TRIMMED P/N 65C34537-11 ANGLE, FLAP PEENED, TREATED, PRIMED AND INSTALLED IAW ASA EA 5310-02318 AND AAR EA 10312.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D CHECK INSPECTION STA 651 FLOORBEAM, BL O REPAIR ANGLE HAS A FASTNER GIVING SHORTED ON P/N 65C34537-11 ANGLE. TRIMMED P/N 65C34537-11 ANGLE, FLAP PEENED, TREATED, PRIMED AND INSTALLED IAW ASA EA 5310-02318 AND AAR EA 10312.