What was found
FORWARD CARGO FLOOR STRUCTURE R/H TRANSITION ANGLE STA. 400 RBL 24 HAS ELONGATED HOLE. (MARKED) ; / [01] DAMAGE IS OUT OF LIMITS IAW SRM 51-40-05.; [02] MATERIAL IDENTIFIED USE BAC1496-444 7075-T6 CLAD FORMED CHANNEL . LOCATED DRILLED UP TO HOLE SIZES PER SRM 51-40-05 . TREATED AND PRIMED PER SRM 51-20-01 .; [03] LOCATED DRILLED UP TO HOLE SIZES PER SRM 51-40-05 . TREATED AND PRIMED PER SRM 51-20-01 . PART WILL BE PAINTED; CIC AND INSTALLED ON BARCODE TTG8006ASSN.; [04] LOCATED DRILLED UP TO HOLE SIZES PER SRM 51-40-05 . TREATED AND PRIMED PER SRM 51-20-01 . PART WILL BE PAINTED; CIC AND INSTALLED ON BARCODE