What was found
AIR TURNBACK, L1 WINDOW HEAT WENT INOP. RETURNED TO OAK PER DISPATCH REQUEST. R&R WINDOW HEAT CONTROLLER & FOUND CANNON PLUG D4640 LOOSE. RECONNECTED AND OPS CHECK GOOD PER MM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.