What was found
AFT CABIN FLOOR STRUCTURE FLOORBEAM AT BS 967, LBL 5-12", WL 208, HAS CORROSION PITTING AROUND NUT PLATE HOLES. REMOVED AND REPLACED SKIN IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN FLOOR STRUCTURE FLOORBEAM AT BS 967, LBL 5-12", WL 208, HAS CORROSION PITTING AROUND NUT PLATE HOLES. REMOVED AND REPLACED SKIN IAW SRM.