What was found
FLOOR SUPPORT UPPER ATTACH ANGLE CRACKED BETWEEN BS 380 TO 400, RBL 12. R & R THE FLOOR SUPPORT ANGLE IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT UPPER ATTACH ANGLE CRACKED BETWEEN BS 380 TO 400, RBL 12. R & R THE FLOOR SUPPORT ANGLE IAW SRM AND DWG.